Siemens SIMATIC VS130 Series Manual page 40

Vision sensor
Table of Contents

Advertisement

Operator Functions
Menu Entry or Parameter
Trigger
Trigger
Control
Control
Pulsetime
Pulsetime
"Read" Submenu
You set the parameters for image evaluation in the "Read" submenu.
Menu Entry
Parameter
Cycletime
Cycle time
Dot Shape
Dot shape
Shutter
Shutter
Brightness
Brightness
5-10
Possible
Default
Values
DP, DI/DO
DI/DO
DP, DI/DO
DI/DO
5 ms to 999 ms 30 ms
Possible
Default
Values
100 ms to
2000 ms
9999 ms
Normal, Bold,
Normal
Separate
1 µs to
200 µs
20000 µs
10 to 500
250
Meaning
Port via which the trigger signal is
supplied to the processing unit
Port for the signals DISA, SEL0,
SEL1, SEL2, SEL3, TRN, RES,
IN_OP, TRD, RDY, READ,
MATCH, N_OK
Pulse time of the digital outputs
READ, MATCH, N_OK
Meaning
Time between two trigger signals
This time is available for image
evaluation.
Shape of the dots in the codes
being read: normal, overlapping,
not touching
Shutter time
Brightness
Vision Sensor VS 130