3.2
Wiring Components
Connect the processing unit with the other components using the connectors on
the front panel. The pinning of the connectors is described in Appendix A.5.
Caution!
!
Do not connect or disconnect cables when the power supply is on.
Apart from the RS-232 cable (6ES7 901-1BF00-0XA0) all the cables are supplied
(see Appendix A.1).
Warning
!
Grounding the VS 130 cancels the ungrounded installation of the power unit used
to operate the VS 130.
IN DC 24V
Connector
Connector Label
Functional earth
-
Power supply
IN DC 24 V
Lighting unit
LAMP
Sensor head
SENSOR
(shielded cable)
I/O
DI/DO
RS-232
RS-232
PROFIBUS DP
PROFIBUS DP
*
The supplied ferrite ring must be fixed to the sensor cable (approx. 50 mm from connector to
processing unit).
Vision Sensor VS 130
A5E00199459-01
LAMP
Type
Screw terminal
Circular connector M12
Circular connector M12
HD Sub D *
Sub D
Sub D
Sub D
Installation
RS232
DP
Number
Cable Cross
of
Section
pins
-
-
2
4
0.56 mm
2
4
0.23 mm
2
26
0.09 mm
2
15
0.14 mm
9
-
9
-
Type
-
Pin
Socket
Socket
Socket
Pin
Socket