Including the Vision Sensor VS 130 in HW Config

The supplied device master data file SIEM8100.GSD contains the PROFIBUS
properties of the VS 130 DP standard slave. If you are using a STEP 7 version
earlier than V5.2 SP1, the Vision Sensor VS 130 is not yet in the modules catalog
in HW Config. In this case, you must add it to the catalog with Options > Install
New GSD... . Remember that the corresponding bitmap file VS1X0__N.DIB must
be in the same folder as the GSD file.
You can also download both files from the Internet at
http://www.ad.siemens.de/csi_e/gsd.
The Vision Sensor VS 130 then appears in the modules catalog under PROFIBUS
DP \ Additional Field Devices \ General \ Machine Vision (see screenshot below).
Vision Sensor VS 130