Siemens SIMATIC VS130 Series Manual page 29

Vision sensor
Table of Contents

Advertisement

Description of the LEDs
LED
SF
POWER
TRAINED
READY
READ
MATCH
N_OK
BF
Setting Numeric Values
You select the places of a value with the arrow buttons " " and " ".
You change the value of a place in the number with the arrow buttons "L" and "M".
The speed at which the numeric value changes depends on how long you press
the arrow buttons. As soon as you release the arrow buttons, the rate of change
returns to the slowest level again.
Vision Sensor VS 130
A5E00199459-01
Function
Group error
Power supply turned on
Trained:
In Run:
0 = selected code has not been trained
-
1 = selected code has been trained
-
In Training (TRN=1):
0 = training active
-
1 = acknowledgment signal (RDY=0)
-
Ready:
0 = device startup or SIMATIC VS 130 in Stop
1 = SIMATIC VS 130 in Run
Result of evaluation: Code was localized and decoded. The LED is lit
when the corresponding output signal changes.
Result of evaluation: Code matches learned code. The LED is lit when the
corresponding output signal changes.
Code was not legible.
Bus error on PROFIBUS