Installing/mounting

3.7 General installation steps

Dimensions in mm (inch)
M12 x 1.75
Set screw
Note
All other installation instructions apply. See General installation steps (Page 14).
3.7
General installation steps
1. Drill out pulley shaft to a depth of 64 mm (2.5 inch) concentric to its centerline.
2. Drill out and thread the set screw hole.
Dimensions in mm (inch)
3. Attach angle iron bracket to work with the arrestor rod (if mounting on a tail pulley).
4. Cut the arrestor rod to a suitable length.
14
WARNING
Remain within specified tolerances
Exercise caution and remain within specified tolerances.
M8 x 1.25 (5/16-18 UNC) set screw (by customer)
16.00 mm (0.630 inch) dia., 16.07 mm (0.633 inch)
M12 x 1.75 [use adhesive when installing
threaded shaft coupling (e.g. Loctite)]