In the "Dot shape" drop-down list box, you set the shape of the dots in the code to
be read:
Normal
Bold: overlapping
Separated: no touching
Immediately after a change in the "Read settings" group, all the current settings of
this group are sent to the processing unit and are therefore active.
Note
The settings sent to the processing unit are saved only after confirming with "OK"
in the Settings > Adjust menu of the processing unit.
If you have activated the "Read" check box in the "Options" group, the color of the
"Shutter speed", "Brightness", and "Cycle time" texts depends on the values in the
input fields. Red text for a parameter means that this setting can lead to an
evaluation problem, as follows:
"Shutter speed" is red when the image is too dark or too light.
"Brightness" is red if you set a value of 300 or higher.
"Cycle time" is red when the time actually required for the codes currently
being read (see "Current image" group) is higher than or equal to 50 % of the
maximum evaluation time set in the "Read settings" group.
"Result" Group
What you see here depends on whether the "Read" check box is selected in the
"Options" group:
If the "Read" check box is not selected, the display is empty.
If the "Read" check box is activated, the last code to be read is displayed.
If the "Original" check box is selected, this is the actual text, if the "Filtered" check
box is selected, it is the text modified according to the parameters of the
Settings>Result menu.
If the data matrix code could not be decoded, the appropriate error message is
displayed here. In contrast to the read code, the error message is red.
Note
Double-clicking on the "Number of images" field in the status bar resets the
image counter to zero.