Siemens SIMATIC VS130 Series Manual page 77

Vision sensor
Table of Contents

Advertisement

I/O Interface "DI/DO" (socket)
Connector Name
1
DISA
2
SEL0
3
SEL1
4
SEL2
5
SEL3
6
TRN
7
TRG
8
RES
9
IN_OP
10
TRD
11
RDY
12
READ
13
MATCH
14
N_OK
15
-
Vision Sensor VS 130
A5E00199459-01
Function
Disable: Disable manual control panel input,
model selection and train via digital I/O
Select 0: Code selection: bit 0
Select 1: Code selection bit 1 / train code
Select 2: Code selection bit 2
Select 3: Code selection bit 3
Train: Train new code
Trigger: An evaluation is started on the positive-
going edge
Reset: Reset error
In Operation:
0 = error message is displayed.
1 = SIMATIC VS 130 functional, no errors
Trained:
In Run:
0 = selected code has not been trained
-
1 = selected code has been trained
-
In Training (TRN=1)
0 = training active
-
1 = acknowledgment signal (RDY=0)
-
Ready:
0 = device startup or SIMATIC VS 130 in Stop
1 = SIMATIC VS 130 in Run
Result of evaluation: Code was localized and
decoded.
Result of evaluation: Code matches learned code.
In the "RUN" mode (evaluation): Code was not
legible.
In the "STOP" mode: set to 0
If there is a group error and during training, the
digital output N_OK is set to "1" at each trigger
signal for the duration of the set pulse time "1".
-
Appendix
Direction
Wire
Color
Input
black
Input
brown
Input
green
Input
orange
Input
yellow
Input
red
Input
blue
Input
violet
Output
white-
black
Output
white-
brown
Output
white-
green
Output
white-
orange
Output
white-
yellow
Output
white-red
-
-
A-13

Advertisement