Beckhoff EL3773 Documentation page 155

Power monitoring oversampling terminal
Table of Contents

Advertisement

Text ID
Type
Place
0x4000
Warning
0x4001
Warning
System
0x4002
Warning
System
0x4003
Warning
System
0x4004
Warning
System
0x4005
Warning
System
0x4006
Warning
System
0x4007
Warning
System
0x4008
Warning
System
0x4101
Warning
General
0x4102
Warning
General
0x417F
Warning
General
0x428D
Warning
General
0x4300
Warning
Encoder
0x4301
Warning
Encoder
0x4400
Warning
Drive
0x4401
Warning
Drive
0x4402
Warning
Drive
0x4405
Warning
Drive
0x4410
Warning
Drive
0x4411
Warning
Drive
0x4412
Warning
Drive
0x4413
Warning
Drive
EL3773
Text Message
Additional comment
Warning: 0x%X, 0x%X,
General warning; parameters depend on event. See
0x%X
device documentation for interpretation.
Warning: 0x%X, 0x%X,
0x%X
%s: %s Connection
Open (IN:%d OUT:%d
API:%dms) from %d.%d.
%d.%d successful
%s: %s Connection
Close (IN:%d OUT:%d)
from %d.%d.%d.%d suc-
cessful
%s: %s Connection (IN:
%d OUT:%d) with %d.
%d.%d.%d timed out
%s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (Error: %u)
%s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (Input Data Size ex-
pected: %d Byte(s) re-
ceived: %d Byte(s))
%s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (Output Data Size
expected: %d Byte(s) re-
ceived: %d Byte(s))
%s: %s Connection
Open (IN:%d OUT:%d)
from %d.%d.%d.%d de-
nied (RPI:%dms not sup-
ported -> API:%dms)
Terminal-Overtempera-
Overtemperature. The internal temperature of the ter-
ture
minal exceeds the parameterized warning threshold
Discrepancy in the PDO-
The selected PDOs do not match the set operating
Configuration
mode.
Sample: Drive operates in velocity mode, but the ve-
locity PDO is but not mapped in the PDOs.
Warning: 0x%X, 0x%X,
0x%X
Challenge is not Ran-
dom
Subincrements deacti-
Sub-increments deactivated (despite activated configu-
vated: %d, %d
ration)
Encoder-Warning
General encoder error
Drive is not calibrated:
Drive is not calibrated
%d, %d
Starttype not supported:
Start type is not supported
0x%X, %d
Command rejected: %d,
Command rejected
%d
Invalid modulo subtype:
Modulo sub-type invalid
%d, %d
Target overrun: %d, %d Target position exceeded
DC-Link undervoltage
The DC link voltage of the terminal is lower than the
(Warning)
parameterized minimum voltage. Activation of the out-
put stage is prevented
DC-Link overvoltage
The DC link voltage of the terminal is higher than the
(Warning)
parameterized maximum voltage. Activation of the out-
put stage is prevented
I2T-Model Amplifier
- The amplifier is being operated outside the specifica-
overload (Warning)
tion
- The I2T-model of the amplifier is incorrectly parame-
terized
Version: 2.5