Beckhoff EL3773 Documentation page 153

Power monitoring oversampling terminal
Table of Contents

Advertisement

Text ID
Type
Place
0x0001
Information
System
0x0002
Information
System
0x0003
Information
System
0x1000
Information
System
0x1012
Information
System
0x1021
Information
System
0x1024
Information
System
0x1042
Information
System
0x1048
Information
System
0x1084
Information
System
0x1100
Information
General
0x1135
Information
General
0x1157
Information
General
0x1158
Information
General
0x1159
Information
General
0x117F
Information
General
0x1201
Information
Communication Communication re-es-
0x1300
Information
Encoder
0x1303
Information
Encoder
0x1304
Information
Encoder
0x1305
Information
Encoder
0x1400
Information
Drive
0x1401
Information
Drive
0x1705
Information
0x1706
Information
0x1707
Information
0x170A
Information
0x170C
Information
0x170D
Information
EL3773
Text Message
Additional comment
No error
No error
Communication estab-
Connection established
lished
 Initialization: 0x%X, 0x
General information; parameters depend on event.
%X, 0x%X
See device documentation for interpretation.
Information: 0x%X, 0x
General information; parameters depend on event.
%X, 0x%X
See device documentation for interpretation.
EtherCAT state change
Init - PreOp
EtherCAT state change
PreOp - Init
EtherCAT state change
PreOp - Safe-Op
EtherCAT state change
SafeOp - PreOp
EtherCAT state change
SafeOp - Op
EtherCAT state change
Op - SafeOp
Detection of operation
Detection of the mode of operation ended
mode completed: 0x%X,
%d
Cycle time o.k.: %d
Cycle time OK
Data manually saved
Data saved manually
(Idx: 0x%X, SubIdx: 0x
%X)
Data automatically
Data saved automatically
saved (Idx: 0x%X,
SubIdx: 0x%X)
Data deleted (Idx: 0x%X,
Data deleted
SubIdx: 0x%X)
Information: 0x%X, 0x
Information
%X, 0x%X
Communication to the field side restored
tablished
This message appears, for example, if the voltage was
removed from the power contacts and re-applied dur-
ing operation
Position set: %d, %d
Position set - StartInputhandler
Encoder Supply ok
Encoder power supply unit OK
Encoder initialization
Encoder initialization successfully completed
successfully, channel:
%X
Sent command encoder
Send encoder reset command
reset, channel: %X
Drive is calibrated: %d,
Drive is calibrated
%d
Actual drive state: 0x%X,
Current drive status
%d
CPU usage returns in
Processor load is back in the normal range
normal range (< 85%%)
Channel is not in satura-
Channel is no longer in saturation
tion anymore
Channel is not in over-
Channel is no longer overloaded
load anymore
No channel range error
A measuring range error is no longer active
anymore
Calibration data saved
Calibration data were saved
Calibration data will be
Calibration data are not applied and saved until the
applied and saved after
command "0x5AFE" is sent
sending the command
"0x5AFE"
Version: 2.5
Diagnosis
153

Advertisement

Table of Contents
loading

Table of Contents