Power monitoring oversampling terminal
Table of Contents

Advertisement

Text ID
Type
Place
0x8000
Error
System
0x8001
Error
System
0x8002
Error
System
0x8003
Error
System
0x8004
Error
System
0x8005
Error
System
0x8006
Error
System
0x8007
Error
System
0x8100
Error
General
0x8101
Error
General
0x8102
Error
General
0x8103
Error
General
0x8104
Error
General
0x8105
Error
General
0x8135
Error
General
0x8136
Error
General
0x8137
Error
General
0x8140
Error
General
0x8141
Error
General
0x8142
Error
General
0x8143
Error
General
0x817F
Error
General
0x8200
Error
Communication Write access error: %d,
0x8201
Error
Communication No communication to
0x8281
Error
Communication Ownership failed: %X
0x8282
Error
Communication To many Keys founded
0x8283
Error
Communication Key Creation failed: %X
0x8284
Error
Communication Key loading failed
0x8285
Error
Communication Reading Public Key
0x8286
Error
Communication Reading Public EK
0x8287
Error
Communication Reading PCR Value
EL3773
Text Message
Additional comment
%s: %s
Error: 0x%X, 0x%X, 0x
General error; parameters depend on event. See de-
%X
vice documentation for interpretation.
Communication aborted Communication aborted
Configuration error: 0x
General; parameters depend on event.
%X, 0x%X, 0x%X
See device documentation for interpretation.
%s: Unsuccessful Fw-
dOpen-Response re-
ceived from %d.%d.%d.
%d (%s) (Error: %u)
%s: FwdClose-Request
sent to %d.%d.%d.%d
(%s)
%s: Unsuccessful Fwd-
Close-Response re-
ceived from %d.%d.%d.
%d (%s) (Error: %u)
%s: Connection with %d.
%d.%d.%d (%s) closed
Status word set: 0x%X,
Error bit set in the status word
%d
Operation mode incom-
Mode of operation incompatible with the PDO interface
patible to PDO interface:
0x%X, %d
Invalid combination of In-
Invalid combination of input and output PDOs
puts and Outputs PDOs
No variable linkage
No variables linked
Terminal-Overtempera-
The internal temperature of the terminal exceeds the
ture
parameterized error threshold. Activation of the termi-
nal is prevented
PD-Watchdog
Communication between the fieldbus and the output
stage is secured by a Watchdog. The axis is stopped
automatically if the fieldbus communication is inter-
rupted.
- The EtherCAT connection was interrupted during op-
eration
- The Master was switched to Config mode during op-
eration
Cycle time has to be a
The IO or NC cycle time divided by 125 µs does not
multiple of 125 µs
produce a whole number
Configuration error: in-
Configuration error: Invalid sampling rate
valid sampling rate
Electronic type plate:
Content of the external name plate memory invalid.
CRC error
Sync Error
Real-time violation
Sync%X Interrupt lost
Sync%X Interrupt lost
Sync Interrupt asynchro-
Sync Interrupt asynchronous
nous
Jitter too big
Jitter limit violation
Error: 0x%X, 0x%X, 0x
%X
Error while writing
%d
- There is no voltage applied to the power contacts
field-side (Auxiliary volt-
- A firmware update has failed
age missing)
failed: %X
failed: %X
failed: %X
Version: 2.5