Audio Port; Ds Ports - Avaya IP Office Essential Edition PARTNER Version Reference Manual

Hide thumbs Also See for IP Office Essential Edition PARTNER Version:
Table of Contents

Advertisement

· Off-Hook Current: 25mA.
IMPORTANT
·
In all IP Office installations, any module being used for analog trunk connections must be connected to a
earth.
WARNING
·
Within areas of high lightning risk, any module using analog trunk connections must be connected to a
ground
and to
surge protection

4.9.2 Audio Port

This port is found on the rear of the control unit. It is used for the input of an external music-on-hold sound source (not
yet implemented in PARTNER® Version). Note that if the IP Office has loaded an internal music-on-hold sound file, any
input from this socket is ignored.
The port is a 3.5mm stereo jack socket suitable for use with the most standard audio leads and connection to the
'headphone' output socket of most audio systems.
The use of a 'headphone' socket allows simple volume adjustment. Connection via a 'Line Out' socket may require
additional equipment in order to adjust the volume level.
· Input impedance: 10k /channel. Maximum a.c. signal – 200mV rms.

4.9.3 DS Ports

These ports are used for connection from an RJ45 structured cabling system to digital station phones supported by the
Essential Edition - PARTNER® Version.
Though the RJ11 to RJ11 cables supplied with most DS phones can be plugged directly into RJ45 ports including those on
Essential Edition - PARTNER® Version modules, this is not recommend as the connection lock is not positive and may
become disconnected.
DS ports on
Digital Station
connection must be made via suitable protective devices at each end and via each building primary protection. In
addition the Digital Station module must be connected to a protective ground.
DS ports on IP 500v2
control units
Structured Cabling Line Cord
This is an RJ45 to RJ11 cable suitable for connection from a structured cabling system RJ45 port to a DS phone. It can
also be used for two-wire analog phone extensions.
IP Office
DS Port
PARTNER® Version, Installation and Reference Manual
IP Office Essential Edition
2
3
4
5
6
7
8
equipment.
Pin No.
Description
Common
Common
Left
Audio In - Left Channel.
Right
Audio In - Right - Channel.
V2 expansion modules can be connected to
must not be connected to out-of-building extensions.
Pin
1
Not used.
Not used.
Ring.
Tip.
Not used.
Not used.
Not used.
out-of-building
Phone
Description
Pin
Not used.
System Component Details: Physical Ports
extensions. If this is the case,
Port
- Issue 1a (30 January 2010)
functional
protective
Page 79

Advertisement

Table of Contents
loading

Table of Contents