Learn

Once entered, the imager starts a procedure to automatically detect and
recognize a single code which is presented to it. Successive Learns will
substitute the current code.
The Learn LED will blink until the procedure is completed.
The Learn procedure ends when the Image Processing and Decoding parameters
are successfully saved in the reader memory, the Green Spot is activated, the
Learn LED will stop blinking and Matrix 120 emits 3 high pitched beeps.
If the autolearning cannot be reached after a timeout of about 3 (three) minutes,
Matrix 120 will exit without saving the parameters to memory, the Learn LED will
stop blinking and in this case Matrix 120 emits a long low pitched beep.
You can exit the Learn function at any time by pressing the X-PRESS push button
once. After a short delay the Learn procedure is canceled.

Diagnostic Indication

The "STATUS" (red) and "READY" (green) LEDs blink simultaneously to signal the
presence of an error. Diagnostic message transmission on interfaces can be
enabled to provide details about specific error conditions. See the Diagnostic
Error Conditions chart in the Diagnostic page of the DL.CODE Monitor.
Product Reference Guide
X-PRESS Human Machine Interface
LED
STATUS
Ready
Blink
Good
Trigger
Com
Status
Blink