Optical Features; Environmental Features - Datalogic Matrix 120 Product Reference Manual

Image based reader
Hide thumbs Also See for Matrix 120:
Table of Contents

Advertisement

Optical Features

Image Format
Frame Rate
a
Focus Range
Factory calibrated positions (mm)
Image Sensor
Pitch
Tilt
LED Safety
Laser Safety (Aiming source)
Lighting System
Aiming System
a. three factory calibrated positions; continuous focus range for fine tuning.

Environmental Features

Operating Temperature
Storage Temperature
Max. Humidity
Vibration Resistance
EN 60068-2-6
Bump Resistance
EN 60068-2-29
Shock Resistance
EN 60068-2-27
Protection Class
EN 60529
Sulfur Gas Test
DIN EN 60068-2-43
a. high ambient temperature applications should use metal mounting bracket for heat dissipation.
Product Reference Guide
a
WVGA
752x480
57 frames/sec.
45 - 70 - 125
CMOS sensor with Global Shutter
 35°
0° - 360°(within vertical FOV)
to EN 62471
IEC60825-1 2007
Internal Illuminator
Laser Indicator
-0 to 45 C (32 to 113 °F)
-20 to 70 C (-4 to 158 °F)
90% non condensing
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 500 Hz; 2 hours on each axis
30g; 6 ms;
5000 shocks on each axis
30g; 11 ms;
3 shocks on each axis
IP65
Passed
Optical Features
MP
1280x960
36 frames/sec.
45 - 80 - 125
155