DL.CODE Installation:
Autorun or Start.hta
doesn't run
Driver Installation
Error:
The ECM driver fails to
install correctly.
Power ON:
the "POWER" LED is
not lit.
One Shot or Phase
Mode using the Input
1 (External Trigger) or
Input 2:
the "TRIGGER" LED is
not blinking while the
External Trigger is
switching.
One Shot or Phase
Mode using serial
trigger source:
the "TRIGGER" LED is
not blinking.
Product Reference Guide
Problem
Check Windows settings to see if Autorun is disabled.
Associate the file type .hta with the Microsoft HTML Applica-
tion host mshta.exe in Windows\System32.
Windows 7 requires that update KB3033929 be installed in
order for the Matrix 120 ECM driver to work properly.
Is power connected?
If using a power adapter (like PG6000), is it connected to wall
outlet?
If using rail power, does rail have power?
If using CBX, does it have power (check switch and LED)?
Check if you are referring to the device / accessory cable or to
the CBX spring clamp connectors.
Measure Voltage either at pin 1 and pin 2 (for 17-pin connector)
or at spring clamp Vdc and GND (for CBX).
Check if you are referring to the 17-pin connector or to the CBX
spring clamp connectors.
Is the sensor connected to Input 1 or Input 2?
Is power supplied to the photo sensor?
For NPN configuration, is power supplied to one of the two I1 or
I2 signals (A or B)?
For PNP configuration, is one of the two I1 or I2 signals
grounded (A or B)?
Are the photo sensor LEDS (if any) working correctly?
Is the sensor/reflector system aligned (if present)?
On the Reading Phase step check the Input 1 or Input 2
Debouncing Time
On the Reading Phase step check the settings for
Trigger, Reading Phase-ON,
ters.
On the Reading Phase step check the settings for
Trigger, Reading Phase-ON,
ters.
Are the COM port parameters (
Bits
) correctly assigned?
On the Reading Phase step check the settings of
Trigger String, Reading Phase-ON String,
OFF String
Is the serial trigger source correctly connected?
Windows XP SP3 and Matrix 120 USB Interface
Troubleshooting Guide
Suggestion
parameter setting.
and
and
parameters.
Acquisition
Reading Phase-OFF
parame-
Acquisition
Reading Phase-OFF
parame-
Baud Rate, Parity, Data Bits, Stop
Acquisition
and
Reading Phase-
151

Hide quick links:

Advertisement

Table of Contents
loading