Setup

1. Enter the Setup function by pressing and
holding the X-PRESS push button until
the Setup LED is on.
2. Release the button to enter the Setup
function. The Setup LED will blink until
the procedure is completed.
The Setup procedure ends when the
Image Acquisition parameters are suc-
cessfully saved in the reader memory,
the Setup LED will stop blinking and
Matrix 120 emits 3 high pitched beeps.
If the calibration cannot be reached after
a timeout of about 5 (five) seconds,
Matrix 120 will exit without saving the
parameters to memory, the Setup LED
will stop blinking and in this case Matrix
120 emits a long low pitched beep.

Learn

1. Enter the Learn function by pressing and
holding the X-PRESS push button until
the Learn LED is on.
2. Release the button to enter the Learn
function. The Learn LED will blink until
the procedure is completed.
The Learn procedure ends when the
Image Processing and Decoding parame-
ters are successfully saved in the reader
memory, the Green Spot is activated, the
Setup LED will stop blinking and Matrix
120 emits 3 high pitched beeps
If the autolearn cannot be reached after
a timeout of about 3 (three) minutes,
Matrix 120 will exit without saving the
parameters to memory, the Learn LED
will stop blinking and in this case Matrix
120 emits a long low pitched beep.
1. The Learn procedure will not recognize the fol-
lowing symbologies: Postal Codes, Pharmacode,
MSI, Standard 2 of 5, Matrix 2 of 5
Product Reference Guide