2. GENERAL
(6) Insulating tape
(C) Damaged
• Install the grommet securely.
(7) Grommet
(A) Correct
• Clamp the electrical wiring securely. Do not
damage the electrical wiring by the clamp.
(8) Clamp: clamped spirally
(9) Electrical wiring
(10) Clamp
• Clamp the electrical wiring correctly. Do not slack,
twist, and pull.
• In cases of connecting the electrical wiring to
moving or vibrating locations, make sure to clamp
the electrical wiring loosely.
2-4
(D) Torn
(B) Incorrect: poor installation
(11) Welding point
D1803-CR-E4,D1803-CR-TE4,D1803-CR-TIE4,V2403-CR-E4,V2403-CR-TE4,V2403-CR-TE4BG,V2403-CR-TIE4
GENERAL WORKING PRECAUTIONS
(12) Electrical wiring
(13) Clamp
(A) Correct
• Do not pinch the electrical wiring when installing
parts.
(14) Electrical wiring

9. Handling fuses

• Always use fuses of the specified capacity.
• Do not use steel or copper wiring instead of fuse.
• Do not install work light or radio without auxiliary
power line.
• Do not install auxiliaries to the fuses. The fuses
may blow.
9. Handling fuses
(B) Incorrect
(B) Incorrect
KiSC issued 12, 2018 A