MECHANISM
9. Aftertreatment system
PM warning level
Automatic active
regeneration
Automatic active
2-1
regeneration
Require parked
2-2
active regenera-
tion
Parked active re-
3
generation (with
output limitation)
Regeneration with
4
Diagmaster (with
output limitation)
Cleaning DPF
5
(with output limi-
tation)
D1803-CR-E4,D1803-CR-TE4,D1803-CR-TIE4,V2403-CR-E4,V2403-CR-TE4,V2403-CR-TE4BG,V2403-CR-TIE4
Regeneration method
Parked active re-
generation
×
×
×
×
×
×
×
Regeneration
Regeneration status
with service
tools
When the warning level
reaches 2, regeneration is
started automatically.
If PM warning level does not
fall to 0 within 30 minutes af-
ter started automatic active
regeneration, parked active
regeneration is required.
Automatic active regenera-
tion stops.
Require parked active re-
generation with machine
stop.
Parked active regeneration
becomes impossible.
Need to use Diagmaster for
regeneration.
Regeneration with Diagmas-
ter becomes impossible.
×
Need to change or clean
DPF.
4. ENGINE
Control
4.
If the DOC temperature
is 550 ℃ (1022 ℉) or
higher, the PM com-
busts on its own so
post injection is not per-
formed (Passive regen-
eration state).
1.
Stop the machine at
safty position.
2.
The
intake
throttle
valve is operated re-
ducing the amount of
intake air raising the
exhaust temperature.
3.
Engine speed is raised
and adjusted so that
the DOC temperature
rises to 250 ℃ (482 ℉)
or higher.
4.
After the DOC reaches
250 ℃ (482 ℉) or high-
er, control is performed
the same as for auto
regeneration.
5.
When regeneration is
finished, the operation
state is returned what it
was prior to auto regen-
eration (idle speed).
Regenerate using diagnostic
tool (Diagmaster).
4-77