3 COMMUNICATIONS VIA OTHER NETWORKS
(Setting example)
Network No.
: 1
Station No.
: 12
IP Address
: (192. 0. 1. 12)
Setting
Network No.
value
Station No.
(Decimal)
IP Address
Setting
Network No.
value
Station No.
(Decimal)
IP Address
Setting
Network No.
value
Station No.
(Decimal)
IP Address
Setting
Network No.
value
Station No.
(Decimal)
IP Address
Setting
Network No.
value
Station No.
(Decimal)
IP Address
Setting
Network No.
value
Station No.
(Decimal)
IP Address
3 - 13
2) Communication relay
receiving station
CPU
E71
E71 module setting details when accessing from CPU 1) to CPU 2)
1) Communication request
source station a)
1, 12
192. 0. 1. 12
E71 module setting details when accessing from CPU 1) to CPU 4)
1) Communication request
2) Communication relay
source station a)
1, 12
192. 0. 1. 12
E71 module setting details when accessing from CPU 2) to CPU 1)
2) Communication request
1)
Setting not necessary
E71 module setting details when accessing from CPU 3) to CPU 4)
1)
Setting not necessary
E71 module setting details when accessing from CPU 4) to CPU 1)
1) Communication request
2) Communication relay
source station b)
1, 12
192. 0. 1. 12
E71 module setting details when accessing from CPU 4) to CPU 3)
1)
Setting not necessary
The a) and b) in the E71 station setting details column indicate whether the value is for
the communication request message transmission or response message transmission.
a): For communication request message transmission
b): For response message transmission
1) Communication request
source station
Network No.
CPU
E71
Station No.
IP Address
Ethernet (Network No.1)
3) Communication relay
sending station
Network No.
: 2
E71
Station No.
: 21
IP Address
: (192. 0. 2. 21)
CPU
E71
4) Communication request
destination station
2)
Setting not necessary
3) Communication relay
receiving station b)
sending station a)
1, 11
192. 0. 1. 11
destination station a)
1, 11
192. 0. 1. 11
3) Communication request
2)
source station a)
Setting not necessary
3) Communication relay
sending station b)
receiving station b)
1, 11
192. 0. 1. 11
2)
Setting not necessary
MELSEC-Q/L
: 1
: 11
: (192. 0. 1. 11)
Ethernet (Network No.2)
Network No.
: 2
Station No.
: 22
IP Address
: (192. 0. 2. 22)
3)
Setting not necessary
Setting not necessary
4) Communication request
destination station b)
2, 22
192. 0. 2. 22
3)
Setting not necessary
Setting not necessary
2, 22
Setting not necessary
192. 0. 2. 22
4) Communication request
destination station a)
2, 22
192. 0. 2. 22
4) Communication request
3)
destination station a)
Setting not necessary
4)
2, 21
192. 0. 2. 21
4)
4)
2, 21
192. 0. 2. 21
2, 21
192. 0. 2. 21
3 - 13

Advertisement

Table of Contents
loading

Table of Contents