2 USING THE E-MAIL FUNCTION
For the main text of e-mail (character string (binary) format)
D0-D19 [CR+LF]
Normal system start completion
2 - 41
<When data format is character strings (binary)>
• The device name and display device No. are recorded for each
setting device.
• When "Condition for inspection" is set to "No conditional settings
(character string send)", "Notification data storage device" records
the data of specified notification points starting from the low byte (L)
of the specified value. (If NULL (00
data immediately before it are recorded.)
• Insert CR (Code: 0D
range.
(Example) Setting "No conditional settings (character strings send)" to
[CR+LF]
ASCII or SHIFT-JIS format values must be set in the Notification data storage
device.
POINT
(1) When e-mail is sent after the result of the device monitoring and the monitoring
condition match, the Subject and attached file, or the Subject and main text will
be sent.
As a device monitoring result, the data that was read from the programmable
controller CPU by the Ethernet module in order to determine whether or not the
conditions match will be sent.
For details on the correspondence between the word device values and the
data format of the attached file, see the figure in Section 2.7.3.
The main text will be sent after converting the data read into ASCII code data.
If the condition for inspection is set to "No conditional settings (character strings
send)" for e-mail text transmission, however, binary code data are sent without
being converted.
(2) When e-mail is sent after the result of the CPU status monitoring and the
monitoring condition match, only the Subject will be sent. The attached file and
main text will not be sent.
(3) Mail contents are not properly displayed on the receiving side when both of the
following conditions are met:
• the format of data notified in the main text is in binary (character string)
• the value set in the news data storage device is in a format other than ASCII
format or SHIFT-JIS format
) and LF (Code: 0A
H
"Condition for inspection", "D0" to "Notification data storage
device", and "20 points" to "Notif. data points":
This means that "Normal system start completion" is stored
in D0 to D19 by the $MOV instruction.
MELSEC-Q/L
) exists in the range, contiguous
H
) for each setting device
H
2 - 41