Mitsubishi Electric Melsec Q Series User Manual page 225

Ethernet interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

6 DEDICATED INSTRUCTIONS
Control data
Device
Execution/abnormal
(S1) + 0
complete type
(S1) + 1
Completion status
Channel used by the local
(S1) + 2
station
Target station's CPU type
(S1) + 3
4
(
)
6 - 58
Item
b15
1) Execution type (bit 0)
0: No arrival confirmation
When the target station is on the same network:
Completed when the data is sent from the local
station.
Execution source
When the target station is on other network:
Completed when the data arrives at the relay
station on the network of the local station.
Execution source
1: With arrival confirmation
Completed when data is written to the target
station.
Complete
Target station
2) Abnormal complete type (bit 7)
Designate whether the clock data setting is required
or not at abnormal completion.
0: Clock data setting not required:
Clock data at error occurrence is not stored in
(S1) + 11 to (S1) + 17.
1: Clock data setting required
Clock data at error occurrence is stored in (S1)
+ 11 to (S1) + 17.
3) Arrival monitoring time unit (bit 8)
Set a unit for arrival monitoring time. Set the arrival
monitoring time to (S1) + 8.
0: Increments of 1s
1: Increments of 100ms
Stores the status at the completion of the instruction.
0
Other than 0: Abnormal (error code) (
Set the channel used by the local station.
1 to 8 (channel)
Specify the programmable controller CPU of the access
destination in the target station.
Setting value
0000
H
03D0
H
03D1
H
03D2
H
03D3
H
03FF
H
Set data
to
b8
b7
0
3)
2)
Complete
Target station
Complete
Relay station
Target station
Execution source
Relay station
Complete
: Normal
Description
Control CPU (The access destination
is the same as that with 03FF
selected.)
Control system CPU (
Standby system CPU (
System A CPU
System B CPU
Control CPU
MELSEC-Q/L
Setting range
to
b0
0
1)
0000
H
0001
H
0080
H
0081
H
0100
H
0101
H
0180
H
Target station
0181
H
3
)
1 to 8
0000
H
H
03D0
to
H
6
)
03D3
H
6
)
03FF
H
(Continued to the next page)
2
Set by (
)
User
System
User
User
6 - 58

Advertisement

Table of Contents
loading