Removing A Dryer Transport Roller Pulley - Kodak X-Omat 480 RA Service Manual

Hide thumbs Also See for X-Omat 480 RA:
Table of Contents

Advertisement

Removing a Dryer Transport Roller Pulley

For this procedure the processor must be deenergized. See page 1-7. In addition, the
RECEIVING-END ACCESS PANEL must be removed from the processor. See pages 1-3
through 1-5 for instructions, if necessary.
[1]
Remove:
• DRYER TRANSPORT ROLLER ASSEMBLY
• PULLEY.
If the PULLEY is tight, it may be necessary to remove the SHAFT and gently tap the SHAFT
loose from the PULLEY. Be careful not to damage the end of the SHAFT.
[2]
To lubricate the new PULLEY, place it in hot water.
[3]
Install the new PULLEY onto the SHAFT.
[4]
Align the new PULLEY.
[5]
Install the DRYER TRANSPORT ROLLER ASSEMBLY.
4-8
IMPORTANT
NOTE
DRYER TRANSPORT
ROLLER ASSEMBLY
Figure 4-7 Removing a Roller Pulley
6.1 cm
(2.4 in.)
0.79 cm
(0.31 in.)
PULLEY
SHAFT
H108_0304BCA
H108_0304BA