Remove the DRAIN VALVE ASSEMBLY from the DRAIN PANEL.
[10]
Remove the 2 NIPPLE/ELBOW/TEE ASSEMBLIES from the OUTPUT SIDES of the DRAIN VALVE.
[11]
Remove the ELBOW from the INPUT SIDE of the DRAIN VALVE.
[12]
On the new DRAIN VALVE, install the parts removed from steps 10 and 11.
[13]
Install the new DRAIN VALVE.
[14]
Reverse the procedure to assemble the DRAIN PANEL.
WATER OUTPUT
TEE
DRAIN VALVE
BRACKET SCREW
TEE
246616
NIPPLE
NIPPLE
DRAIN VALVE
Figure 5-22 Removing the Drain Valve Bracket
DRAIN VALVE
NIPPLE
DRAIN VALVE
BRACKET SCREW
NIPPLE
ELBOW
ELBOW
H108_0151DCA
H108_0151DC
5-25