Kodak X-Omat 480 RA Service Manual page 114

Hide thumbs Also See for X-Omat 480 RA:
Table of Contents

Advertisement

[4]
Remove the DEVELOPER HEAT EXCHANGER COVER from the bottom of the DEVELOPER TANK.
[5]
Wash the DEVELOPER HEAT EXCHANGER COVER with developer system cleaner.
[6]
Rinse the DEVELOPER HEAT EXCHANGER COVER thoroughly with water to remove all of the
developer system cleaner.
[7]
Install the DEVELOPER HEAT EXCHANGER COVER into the bottom of the DEVELOPER TANK.
[8]
Install all parts removed in previous steps.
7-8
DEVELOPER
TANK
DEVELOPER
HEAT EXCHANGER
COVER
Figure 7-6 Removing the Developer Heat Exchanger Cover
HEAT
EXCHANGER
H108_0118CCA
H108_0118CA
246616