Adjustment Ranges Sidoor Meg250 - Siemens SIDOOR AT40 System Manual

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

A.1.10.2

Adjustment ranges SIDOOR MEG250

Table A- 26
Adjustment ranges SIDOOR MEG250 L / R
Parameter
Creep distance OPEN
Cutter distance OPEN
Creep distance CLOSE
Cutter distance CLOSE
Maximum speed OPEN
Creep speed OPEN
Cutter speed OPEN
Initial speed OPEN
Maximum speed CLOSE
Creep speed CLOSE
Cutter speed CLOSE
Initial speed CLOSE
Nudge speed CLOSE
Acceleration ramp OPEN
Braking ramp OPEN
Reversing ramp OPEN/CLOSE
Acceleration ramp CLOSE
Braking ramp CLOSE
Reversing ramp CLOSE/OPEN
Continuous torque (power) OPEN
Continuous torque (power) CLOSE
Cutter press-on torque
Static opening force
Static closing force
Static cutter force CLOSE
Static nudge force CLOSE
The parameter is accepted with the door stationary at the end stop "CLOSED" or end stop
"OPEN".
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Unit
Adjustment range
ATE250S
mm
0 ... 100
mm
0 ... 100
mm
0 ... 100
mm
0 ... 100
mm/s
100 ... 750
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
100 ... 500
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
50 ... 250
mm/s
300 ... 1400
2
mm/s
300 ... 1000
2
mm/s
300 ... 1000
2
mm/s
300 ... 1400
2
mm/s
300 ... 1000
2
mm/s
300 ... 1000
2
A
0 ... 3.3
A
0 ... 3.3
A
0 ... 12.8
N
70 ... 300
N
70 ... 230
N
70 ... 230
N
70 ... 230
A.1 Profiles and adjustment ranges
Appendix
325

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents