Controllers
6.2 Drive functions
6.2.42

Output transmission

Description of function
For the M4, MDG400. MDG400 NMS and M5 motors, the output transmission must be
configured. The output transmission describes the transformation of rotational into
translational motion. Therefore: The distance [mm] that the door travels with one revolution
[rev] of the transmission output shaft. The output transmission can be adjusted within the
range 0...384 mm/rev. The permitted values are between 88...384 mm/rev. The default value
for a newly trained motor type is 0 mm/rev.
Output transmission
[mm/rev]
Door weight [kg]
Note
For the M4, MDG400 and M5 motors, set default value to 176 mm/rev.
Note
The output transmission should be checked before each learn run and adjusted if necessary.
Note
The determined door width has to be checked after each learn run.
Note
Activation of the learn run via the bus interface
The learn run can only be started when an allowable value has been entered. The value for
the door width should then be read back via the parameter r2103 and checked.
Connection and parameter assignment
The force limit can be configured via the terminal module (
Special parameters > Output transmission
SIDOOR ATD410W / ATD420W / ATD430W
The output transmission is set via the parameter p4602. See section Calibration and function
parameters (Page 175) for more on this.
86
< 200
100
X
200
X
300
X
400
X
).
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
< 250
< 300
X
X
X
X
X
n.r.
n.r.
n.r.
n.r. not recommended
Main menu > General setup >
System Manual, 06/2016, A2B00096162-AN
< 384
X
n.r.
n.r.
n.r.