6.8

Diagnostics

6.8.1

Operating state display

Operating states are indicated on the "H401" 7-segment display or the "H1" digital display.
The SIDOOR ATD410W/ATD420W/ATD430W controllers additionally enable retrieval of
status information via the parameter r2100 ("status code").
The following operating states are shown:
Display
Description
Info
0
Light barrier/pressure-sensitive edge
1)
6
Motor obstructed in the closing direction
8
Minimal editor is started (press the service buttons OPEN and CLOSE simultaneously at power on).
2)
A
Minimal editor (force setting) active
c
Obstruction while opening
C
Minimal editor (profile setting) is active
2)
d
Door remains stationary during initialization run (no OPEN or CLOSE signal present, or door has reached
end position)
H
Determination of parameters (learn run)
o
Function OK
r
CAN error
3)
u
Door closed
Fault
1
RAM, EEPROM or CPU error (system error)
2
Braking chopper defective
3
Error in the second shutdown route
4
Motor protection, maximum opening or closing time of 65 s has been exceeded
4)
5
Motor undefined – no learn run carried out with this motor type
(If a different motor version is used, the learn run must be repeated at power on as described in these Op-
erating Instructions. See Table 6-13 Starting a learn run when the line voltage is applied (Page 111))
7
Error in pulse generator
8
OSSD (type 2 ESPE or pressure-sensitive edge) – function test failed
4)
9
Motor overcurrent
E
Motor overvoltage
F
Motor undervoltage
G
Belt break
5)
I
Hall sensor fault
5
n
Output stage defective
L
Current measurement error
t
Belt torn
4) 6)
4) 6)
U
Maximum door weight exceeded
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
interrupted
4)
6.8 Diagnostics
4)
4)
Controllers