Sidoor Mdg400Nms Adjustment Ranges - Siemens SIDOOR AT40 System Manual

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

A.1.8.2

SIDOOR MDG400NMS adjustment ranges

SIDOOR ATD4xxW
Table A- 20
Parameters
Creep distance OPEN
Cutter distance OPEN
Creep distance CLOSE
Cutter distance CLOSE
Maximum speed OPEN
Creep speed OPEN
Cutter speed OPEN
Initial speed OPEN
Maximum speed CLOSE
Creep speed CLOSE
Cutter speed CLOSE
Initial speed CLOSE
NDG speed (reduced)
Acceleration ramp OPEN
Brake ramp OPEN
Reversing ramp OPEN/CLOSE
Acceleration ramp CLOSE
Brake ramp CLOSE
Reverse ramp CLOSE/OPEN
Continuous torque (power) OPEN
Continuous torque (power) CLOSE
Cutter press-on torque
Static opening force
Static closing force
Static cutter force CLOSE
Static NDG force (reduced)
Limit energy close
Limit energy open
Limit energy NDG
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
SIDOOR MDG400NMS L / R adjustment ranges
Parameter
ID
p3660
p3661
p3662
p3663
p3664
p3665
p3666
p3667
p3668
p3669
p3670
p3671
p3672
p3673
p3674
p3675
p3676
p3677
p3678
p3679
p3680
p3681
p3682
p3683
p3684
p3685
p1202
p1203
p1204
A.1 Profiles and adjustment ranges
Unit
Adjustment range
ATD4xxW
mm
0 ... 100
mm
0 ... 100
mm
0 ... 100
mm
0 ... 100
mm/s
30 ... 800*k1
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 800*k1
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 90
mm/s
30 ... 800*k1
mm/s2
300 ... 1400*k1
mm/s2
300 ... k2
mm/s2
300 ... k2
mm/s2
300 ... 1400*k1
mm/s2
300 ... k2
mm/s2
300 ... k2
A
0 ... 2.5
A
0 ... 2.5
A
0 ... 5
N
70 ... 360/k1
N
70 ... 360/k1
N
70 ... 360/k1
N
70 ... 360/k1
J
0 ... 100
J
0 ... 100
J
0 ... 100
Appendix
319

Hide quick links:

Advertisement

Table of Contents
loading