Siemens SIDOOR AT40 System Manual page 173

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

Parameter ID
Adjustment range
r2105
Display and operation
p90
0 ≙ deactivated
1 ≙ activated
p91
Write:
1 ≙ reset complete pa-
rameter set (load all
factory defaults)
Read:
1 ≙ parameter set vali-
dated and valid
0 ≙ parameter set invalid
and/or reset to factory
settings
p92
1 ≙ load factory defaults
of the FBLOCK parame-
ter set
p93
1 ≙ load factory defaults
of the driving curve pa-
rameter set
p100
0 ≙ bus system
1 ≙ reserved
2 ≙ FBLOCK (digital
inputs)
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Factory
Unit
setting
[N]
0
0
Description
System friction in the closing direction determined
during the learn run (the friction of the drive system
is not included here)
Write protection
Activates (1) or deactivates (0) write protection for
all driving curve parameters in the service menu.
Attention: All saved parameters are reset to factory
setting!
Note: A learn run is mandatory for "0" (parameter
set invalid or factory settings loaded)!
Note: all saved FBLOCK parameters are reset to
their factory defaults!
Note: all saved driving curve parameters are reset
to their factory defaults!
Loads driving curve parameters of the default
driving curve profile
p1202 and p1203 are also reset
Default command issuing via: bus system, reserved
or FBLOCK (digital inputs)
Controllers
6.7 Parameters
173