6.10

Communication to PROFINET

6.10.1

Parameterization/startup record

When setting up a connection, the startup parameter record (record 1) is sent from the IO
controller to the ATD430W as specified in the GSD file (see Table 6-28 GSD files
(Page 150)). Only the cycle time parameter is visible in the configuration tool.
The structure of the 8-bytes-long startup parameter record 1 is described below (for
informational purposes only):
Table 6- 52
Bit
7
0
Table 6- 53
Bit
7
0
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Startup parameter record byte 1
Bit
Bit
Bit
Bit
Bit
6
5
4
3
2
X
X
X
0
0
Startup parameter record byte 2
Bit
Bit
Bit
Bit
Bit
6
5
4
3
2
X
X
X
0
0
Bit
Bit
Data exchange and baud rate parameter
1
0
X
Data communication
Data communication on the internal bus is deactivated if
this bit is set to 0.
Default = 1 (activated)
X
Baud rate
The baud rate is set with bits 1 to 4. The following coding
results:
9600 = 0000
19200 = 0001
38400 = 0010
57600 = 0011
115200 = 0100
187500 = 0101
250000 = 0110
300000 = 0111
375000 = 1000
500000 = 1001
750000 = 1010
Default = 11520
Reserved
Bit
Bit
Slave address parameter
1
0
X
X
Slave address
The slave address on the internal bus is set via bits 0 to 4.
The address range is from 0 to 31.
Default = address 0
Reserved