Parameter Id; Parameter Description (Pbe) - Siemens SIDOOR AT40 System Manual

Automatic door controls
Hide thumbs Also See for SIDOOR AT40:
Table of Contents

Advertisement

6.11.1.4

Parameter ID

The parameter ID comprises the PNU (array within PKE) and the page index (array within
IND). In general, the parameter ID name is simplified to just PNU (parameter number).
SIDOOR controllers support parameter numbers in the range from 0 to 65535. The exact
assignment of the parameter number is described in Section Parameter assignment
(ATD4xxW) (Page 170).
6.11.1.5

Parameter description (PBE)

The notation of the parameter description states the element number of the parameter
description in the IND array subindex.
Table 6- 69
Element number
0
1
2
3
4
5
6
7
8
9
10 ... 15
The subindex 255 for transferring a complete parameter description or a complete array
requires a variable telegram length which is not currently supported.
The designation ID (element number 1) consists of the following bits:
Bit
0 ... 7
8
9
10
11
12
13
14
15
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
Elements of the parameter description
Description
Reserved
Designation ID
Number of array elements
Reserved
Reserved
Reserved
Reserved
Lower limit value
Upper limit value
Default value (factory setting)
Reserved
Description
Data type of the parameter value
Scaling and major attribute relevant
Write-protected
Additional text available
Reserved
Parameter differs from factory settings
Parameter can only be reset
Parameter is an array
Reserved
6.11 Structure of user data/process data
Data type
16 bit
8 bit
16 bit
16 bit
16 bit
Controllers
203

Hide quick links:

Advertisement

Table of Contents
loading