Advertisement

Performing a learn run
Note
The current driving parameters are overwritten by the factory parameters at the end of the
learn run if the learn run button (S401) is pressed at the same time as the line voltage is
applied. If the learn run button is pressed during operation, only the door width and weight
are determined. The driving parameters, force limits and continuous torques remain
unchanged. The maximum closing speed and the nudge speed are limited as a function of
the determined weight.
1. Push the door into the CLOSED position.
2. Perform a learn run during operation. Proceed as described in Table 6-14 Starting a learn
run during operation (Page 112).
Deactivating (exiting) the minimal editor
1. Disconnect the controller from the power supply by unplugging the power plug.
2. Connect the controller to the power supply by plugging in the power plug.
Note
The line voltage can alternatively be connected and disconnected with the X3 connector
directly on the controller.