Type 2063, 2064, 2065
Technical data
Ports
Pilot air port
Stainless steel threaded bushing G1/8
M5 (for actuator size ø 32 mm)
Port connection
Welded connection:
according to EN ISO 1127 (ISO 4200), DIN
11850 R2, DIN 11866 (ASME-BPE)
other connections on request
7

INSTALLATION

DANGER!
Risk of injury from high pressure in the system.
▶ Before working on the device or system, switch off the pressure.
Vent or empty the lines.
WARNING!
Risk of injury due to improper installation.
▶ Installation may only be performed by qualified and trained
personnel.
▶ Ensure a controlled restart after installation.
For control function I: Risk of pilot pressure failure.
The valve stays in an undefined position in the event of a pilot
pressure failure.
▶ To ensure a controlled restart, first pressurize the device with
pilot pressure, then switch on the medium.
Risk of injury due to unintentional activation of the system
and uncontrolled restart.
▶ Secure the system against unintentional activation.
▶ Ensure a controlled restart after installation.
CAUTION!
Risk of injury due to heavy device.
During transportation or installation work, a heavy device may
fall down and cause injuries.
▶ Transport, install and remove heavy device with the aid of a
second person only.
▶ Use suitable tools.
7.1

Installation position 2/2-way valves

The piston-controlled diaphragm valve can be installed in any
position, preferably with the actuator facing up.
Installation for leakage detection
One of the holes in the diaphragm socket for monitoring
the leakage must be at the lowest point.
Ensuring self-draining
It is the responsibility of the installer and operator to
ensure self-draining.
The following points must be observed during installation
regarding self-draining:
• Inclination angle of the pipeline:
The inclination angle of the diaphragm valves is the responsi-
bility of the installer and operator and should correspond to the
inclination angle of the pipeline. For the pipeline we recommend
the inclination angles according to the valid ASME BPE.