3-4-2 Operation procedure with external control

⿎ Operation example when controlling the laser marker from external control devices such as
PLC
Turn ON key switch of laser marker controller
Remote mode ON
Refer to "3-4-4 Remote mode settings" (P.67).
I/O control
Select file
Laser pumping ON
OPEN shutter
Confirm READY OUT is ON.
The device is ready for receiving the marking starting signal (trigger).
Trigger Input ON
• It is available to the external control combining I/O, and serial communication commands.
• You need to configure the system settings on the I/O communication in advance before using external control. Refer to
"3-4-3 Settings before external control" (P.64).
• For details on the operation procedure when you link an image checker or a code reader, refer to "6 Link Control with
External Devices" (P.116).
Control by serial communication
commands
Marking
ME-LPGS-SM-8
Control by using I/O or
communication commands
63