3-1-2 Operation procedure with external control

„ Operation example when controlling the laser marker from external control devices such as
PLC
Turn ON key switch of laser marker controller
Remote mode ON
Refer to "3-2-3 Shift to remote mode" (P.76).
I/O control
Select file
Laser pumping ON
Open shutter
READY output ON
The device is ready for receiving the marking starting signal (trigger).
For LP-Mxxx-S type, open the laser gate to turn ON the ready signal.
Marking trigger input ON
• It is available to combine I/O and the serial communication for external control.
• Configure the environment setting in advance before using external control. Refer to "3-2 Before External Control"
(P.72).
Control by serial communication commands
about 20 seconds
Marking (Laser radiation)
ME-LPM-SSM-10
Control by using I/O
or communication
commands