2-5 Connecting Laser Marker
WARNING
2-5-1 Connection of head and controller
• It is recommended to connect the head and controller that have the identical serial numbers.
• For the connection of this product, use the dedicated cables attached to the product or the specified optional cables.
• Insert the cable all the way in a straight line. Tilting and inserting the cable may cause a failure.
• Be careful not to apply excess force to the cable or not to nip the cable at the installation.
• Verify the minimum bend radius of each cable and install them without excess forces being applied.
Rear of head
No.
Cable and connector
Signal cable
q
Unit power cable
w
I/O terminal block
e
• Connect the following terminals of the I/O terminal block. If any of them is not connected, the laser radiation is disabled.
When shipped, these terminals are connected with a short bar. (The power supply part is connected by NPN connection.)
IN COM. 1 (X2)
OUT COM. 1 (Y2)
LASER STOP 1 IN (X10)
LASER STOP 2 IN (X11) *2
INTERLOCK 1(+) (X16)
INTERLOCK 2(+) (X18)
*1 : NPN Connection wiring. For wiring by PNP connection or external power supply, remove the short bar and wire them
again. For details, refer to "4-5 Connecting I/O Terminal Block" (P.88).
*2 : For X11, you can select its behavior from LASER STOP 1 IN or LASER STOP 2 IN by the setting of LASER MARKER
NAVI smart. (Initial setting: LASER STOP 2 IN)
• Be sure to turn the power off before you conduct wiring or connection. Failure
to do so may cause electrical shock.
• Be sure to connect the head and controller of the laser marker which have the
same model number. Otherwise there is a risk of exposure to laser radiation
or failure.
Connector
Signal connector: SIGNAL
Power connector: POWER
I/O terminal block connector: TERMINAL
―
24V OUT (X1) *1
―
0V OUT (Y1) *1
―
OUT COM. 1 (X12)
―
OUT COM. 1 (X12)
―
INTERLOCK 1(-) (X17)
―
INTERLOCK 2(-) (X19)
ME-LPGS-SM-8
q
w
e
Rear of controller