ERROR
CODE
Insufficient marking memory. Marking data in the
E661
file are too large.
The number of Step & repeat marking exceeds
E662
the upper limit.
One or more functions that cannot be used
together are set.
The following combination of the functions are
not available in one file.
• Characters specified by SIN command and
registered characters via I/O
• Characters specified by SIN command and
E664
external offset function with I/O
• Registered characters via I/O and external
offset function with "Using SEO command"
• Link control with an image checker and
"continuous trigger" of trigger mode
• For LP-RC/LP-RF/LP-RV series:
Link control with an image checker and
TARGET DETECTION IN
It contains character(s) that cannot be converted
E665
to 2D code.
• Unable to generate 2D code in the condition
specified.
E666
• The number of 2D code characters is too
large relative to the set conditions.
The specified 2D code filling pattern is not
E667
registered for the 2D code font (font number:
2D).
The data includes a character that cannot be bar
E668
coded.
• Unable to generate bar code in the condition
specified.
E669
• The number of bar code characters is
incorrect relative to the set conditions.
The dimensions of the narrow element or the
E670
module width for the bar code are too small.
The quiet zone is not configured correctly at the
E671
bar code inversion mode settings.
182
Description
ME-LPGS-SM-8
Measures *1
• Reduce the number of characters and segments
in the graphic data.
• Reduce the number of characters and start/end
points of the graphic data.
• Reduce the number of markings for Step & repeat.
• Separate the long segment into short data.
Reduce objects to be marked to 10000 or less.
Delete any one of these functions from the file.
• Set the character that can be converted into 2D
code.
• Change the mode of the code settings.
Check the code settings and the number of
characters.
• Change the 2D code filling pattern.
• Add the font data of the pattern used in the data
management screen.
Set characters that can be bar-coded depending on
the code type.
Check the code settings and the number of
characters.
Specify the setting value for the narrow element or
the module width larger than that of the "line width
(calculation value)" specified in the object group
settings.
Set the proper value for "Quiet/Narrow Ratio".