Panasonic LP-GS Series Setup & Maintenance Manual page 123

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

6.
When the application of the image checking
after marking is set to "Code checking" or
"Character checking", input "Object number to
check" that is the same number with the object
number you set in barcode/2D code settings or
character settings.
7.
If you use PV230/PV200 for image checking
after marking, input the following items, so that
the setting values are same with the settings in
PV230/PV200.
• Type number set on PV
• For code checking: CDR checker number set on PV
• For character checking: OCR checker number set on PV
• If there is no type number applicable to the image checker (PV230/PV200) setting data, the linkage function cannot be
used. Check that the type specified here is consistent with the image checker (PV230/PV200) setting.
• When the application is set to code checking and if you want to check the code symbol and human readable text at the
same time, set CDR checker number for the code symbol and OCR checker number for the human readable text.
8.
Overwrite the file after setting completion.
ME-LPGS-SM-8
123

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading