Set The Laser Marker Communication Settings - Panasonic LP-GS Series Setup & Maintenance Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

6-1-4 Set the laser marker communication settings

1.
Connect the laser marker and Laser Marker NAVI smart online.
2.
Select "System settings" from the Screen selection menu, and click the "Communication" tab.
3.
Set the Ethernet communication configuration
of the laser marker.
4.
View the "Image checker" panel items
and configure the communication settings
according to the functions to use.
For image checking before marking:
• IP Address
For image checking after marking:
• Model of image checker: PV230/PV200, DataMan, LP-
ABR
• IP Address
• Port (for LP-ABR and DataMan)
• Specify these values according to communication settings
of the image checker to connect.
• The Port number for PV230/PV200 is a fixed value.
• Specify Telnet Port for DataMan port number.
• For LP-ABR, set the port number with the same value of "Data Port No" in Configurator LP-ABR.
5.
Click "Set" on the lower right corner of the screen.
6.
Disconnect the online connection with the laser marker.
7.
Turn OFF the laser marker power and wait for five seconds or more, then restart.
The configured items will be reflected to the laser marker.