4-6-10 Counter reset input

SELECT 0 - 2 IN (No.19-21)
D0 - D15 IN (No.3-18)
SET IN (No.2)
TRIGGER IN (X5)
SET OK OUT (No.28)
READY OUT (Y5)
PROCESSING OUT (Y10)
Item
Time
T1
2ms or more
T2
0ms or more
T3
2 to 510ms
T4
0ms or more
T5
0.5ms or more
*1 : To reset the counter, set SELECT 0 IN to SELECT 2 IN as follows.
SELECT 0 IN (No.19): OFF, SELECT 1 IN (No.20): OFF, SELECT 2 IN (No.21): ON
*2 : Specify the counter number to reset by using D0 IN to D15 IN (No.3 to 18). The following counter numbers are
assigned to D0 IN to D15 IN respectively.
• D0 to D3: Counter No. 0 to 3
• D4 to D7: Common Counter No. 16 to 19
• D8 to D11: Counter No. 4 to 7
• D12 to D15: Common Counter No. 20 to 23
102
ON
OFF
ON
OFF
ON
OFF
T1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Remarks
Keep the ON status for 2ms or more.
Keep the input until SET OK OUT (No.28) turns on.
One-shot output. Set the output time on the system settings screen. There is a small
margin of error for the setting value.
Turn on TRIGGER IN (X5) after SET OK OUT (No.28) turns on.
After a lapse of 0.5ms or more from specifying SELECT 0 IN to SELECT 2 IN and D0 IN to
D15 IN, turn on SET IN (No.2).
ME-LPGS-SM-8
*1
*2
T5
T2
T1
T3
T4