Shutter Open/Close - Panasonic LP-GS Series Setup & Maintenance Manual

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

4-6-2 Shutter open/close

LASER STANDBY OUT (Y6)
TRIGGER IN (X5)
SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
SHUTTER OPEN 1 OUT (Y8)
SHUTTER OPEN 2 OUT (Y9)
READY OUT (Y5)
PROCESSING OUT (Y10)
PROCESSING END OUT (Y11)
*1 : SHUTTER IN (X8) is accepted and the shutter opens only when SHUTTER ENABLE IN (X9) is turned on.
*2 : If SHUTTER IN (X8) was turned off during the trigger processing, the shutter closes after the trigger processing has
completed.
Item
Time
T1
Max. 1 sec.
T2
T3
2ms or more
T4
T5
2 to 510ms
94
ON
OFF
ON
OFF
ON (Open)
OFF (Close)
*1
ON (Open)
OFF (Close)
T1
ON (Open)
OFF (Close)
ON (Open)
OFF (Close)
ON
T2
OFF
ON
OFF
ON
OFF
Remarks
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTER
OPEN 2 OUT (Y9).
SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be output by the same
operation, but their output timing has a margin of error.
Total time for shutter opening (T1) and marking data creation. It varies depending on the
quantity of the setting data.
Keep the ON status for 2ms or more.
When TRIGGER IN (X5) is accepted, PROCESSING OUT (Y10) turns ON. The output time
of PROCESSING OUT (Y10) includes the trigger delay time, marking preparation time,
laser radiation time, and processing time after marking has completed.
If you are not using the link function with external devices, output time of PROCESSING
OUT (Y10) is almost the same as the total duration of the trigger delay time and LASING
OUT (Y20).
One-shot output. Set the output time on the environment setting screen.
There is a small margin of error for the setting value.
ME-LPGS-SM-8
T1
T1
T1
T1
T2
T2
T3
*2
T1
T4
T5

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents