4-6-13 Laser stop 2 input

If LASER STOP 2 IN is released, the laser pumping is turned off and the shutter is closed, regardless of whether or not the
laser is radiating. Refer to "Laser marker operation when functions for safety measures are input" (P.77).
LASER SUPPLY IN (X6)
SHUTTER ENABLE IN (X9)
SHUTTER IN (X8)
TRIGGER IN (X5)
LASER STOP 2 IN (X11)
ALARM RESET IN (X15)
LASER STANDBY OUT (Y6)
SHUTTER OPEN 1 OUT (Y8)
SHUTTER OPEN 2 OUT (Y9)
READY OUT (Y5)
PROCESSING OUT (Y10)
PROCESSING END OUT (Y11)
PROCESSING FAIL OUT (Y12)
ALARM OUT (Y15)
Item
Time
T1
Max. 1 sec.
T2
100ms or more
T3
Approx. 8 to 15 sec.
T4
T5
2ms or more
T6
2 to 510ms
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T2
ON (Close)
OFF (Open)
ON
OFF
ON (Open)
T1
OFF (Close)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON (Normal)
OFF (Error)
Remarks
There is a delay time of around 200ms to max. 1 second from turning ON/OFF of
SHUTTER IN (X8) to turning ON/OFF of SHUTTER OPEN 1 OUT (Y8) and SHUTTER
OPEN 2 OUT (Y9).
SHUTTER OPEN 1 OUT and SHUTTER OPEN 2 OUT will be output by the same
operation, but their output timing has a margin of error.
Keep the ON status for 100ms or more.
Time for completion of laser pumping.
• Normal: Approx. 8 sec.
• Re-pumping right after turning the laser pumping off: Approx. 15 sec.
Total time for shutter opening and marking data creation, or time for laser pumping,
whichever is longer.
Keep the ON status for 2ms or more.
This is One-shot output. Set the output time on the environment setting screen. There is
a small margin of error for the setting value.