5-2-2 Communication settings (for command control)

Item
Synchro system
Communication type
Baud rate
Data length
Parity
Stop bits
Flow control
Check sum
End code
Start code *
Response data command *
Response data sub
command *
Character code
Encoding for 2-byte
characters *
Reception timer
* If you set "LP-400/V compatibility" in the system settings of Laser Marker NAVI smart, the same command format
with the former models of LP-400/LP-V series is applied regardless these settings. For the details, refer to the "Serial
Communication Command Guide: LP-400/V compatible mode".
• For the details of the communication settings, refer to "3-4-3 Settings before external control" (P.64).
RS-232C communication settings (for command control)
Start-stop method
Full-duplex transmission
1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps (initial setting: 9600 bps)
8-bit fixed
None / Even / Odd (initial setting: None)
1-bit / 2-bit (initial setting: 1-bit)
None
OFF / ON (initial setting: OFF)
CR / CR + LF (initial setting: CR)
ON (STX) / OFF (initial setting: STX)
ON / OFF (initial setting: ON)
Any single byte character of ASCII code from 01 (HEX) to 7F (HEX) can be specified.
• Initial setting of positive response code: A
• Initial setting of negative response code: E
• Initial setting of read request response code: A
ASCII code
Shift-JIS / GB 2312 (initial setting: Shift-JIS)
Timeout monitoring ON (10 sec.)