No.
Name and description
36
TIMING WAIT OUT: Timing wait output
This is the terminal you will use when the link control function with the image checker is configured.
This terminal turns ON when the laser marker enters into the link function operation trigger (TIMING IN)
standby state.
Input TIMING IN (No.24) after making sure that this terminal is turned ON.
37
SCRIPTING OUT: Scripting output
This is the terminal you will use when the link control function with the image checker is configured.
This terminal turns ON while executing scripting (laser marker's internal processing to perform the link control
of the external devices) upon receiving TRIGGER IN (X5). The output time of SCRIPTING OUT does not
include the laser radiation time.
38
N.C.: Not connected
Do not connect externally.
39
N.C.: Not connected
Do not connect externally.
40
N.C.: Not connected
Do not connect externally.
*1 : Set the output time of the one-shot output on the system settings screen of Laser Marker NAVI smart. The setting range is
2 to 510ms. The initial setting value is 40ms. One-shot output time has a small margin of error for the setting value.