2.1.3 HOW TO USE [CREATE/NAME SITE] SETUP
Use this command to create a new Site Setup from the [Channel/Path] menu. This is the first
action required for an original installation. The [Create/Name Site] function inserts system
defaults in all the appropriate menu cells. You can edit these defaults as necessary to suit
your needs.
You do not have to provide a site name in order to create a new Site Setup. You can create a
site simply by pressing
This creates a "nameless" Site Setup. However, if you intend to use the meter's multi-site
storage facility, you must enter a unique site name for each site setup you want to retain in the
site storage memory.
To create and name a new Site Setup:
To access the first character position press
On a PC keyboard, type the name of the new Site Setup (8 characters max.) and the
press
to create and name the new site.
ENT
Press
to select a character, then press
tion.
To select the second character press
Repeat this process to select all the characters (8 max.) you want to use to identify the new
Site Setup.
To create the new Site Setup press
NOTE: If you decide to use numbers or a decimal point in the site name, you can type
these characters directly from the PC keyboard.

2.1.4 HOW TO ENABLE/DISABLE SITE SECURITY

With [Site Security] enabled, the meter will require a password before it allows any activity
that could interrupt or affect system operation. You can still access the Installation Menu.
However, [Site Security] limits access to the viewing of parameters only. In other words, you
will still be able to review site data, but you will not be able to make any changes.
Activate Site Security with care. Once activated, the only way to deactivate it is via the Site
Security [Off] command. However, the cursor will not move to the [Site Security] ON/OFF
option list until you enter the correct password. Therefore, it is essential that you never for-
get or misplace the password. The only way to deactivate [Site Security] without know-
ing the password is to return the unit to Controlotron. The flowmeter will allow a <F4> Reset
Sequence when Security is active, however, it also contains a Menu Enable switch that allows
you to inhibit this function (see drawing 1010BX-7).
CAUTION: MAKE CERTAIN THAT YOU RETAIN A COPY OF THE PASSWORD IN A SE-
CURE LOCATION.
To activate Site Security:
To access [Site Security] option list press
to access the menu cell entry field and then pressing
ENT
2-4
to highlight to next character posi-
1010BXFM-3
.