Siemens SITRANS F FUH1010 Series Operating Instructions Manual page 100

Nema 7 compact interface detector
Table of Contents

Advertisement

Section 2
IMPORTANT
The Sonilocator function will not operate unless the [Sonilocate] menu item is selected
in the Datalogger Setup menu.
To select the [Sonilocate] menu item, proceed as follows:
At the [Meter Type] Menu, press the <Right Arrow> key and then the <ENT> key to
select the desired Path (e.g., Dual Path Flow).
In the [Dual Path Flow] Menu, press the <Down Arrow> key and scroll to the
[Datalogger Setup] menu cell. Press the <Right Arrow> to select it.
Press the <Up/Down Arrow> key and scroll to the [Datalogger Data] menu cell.
Press the <Right Arrow> key to highlight Datalogger Data option list items.
Controlotron
Dual Path
Datalogger Mode
Datalogger Data
Log Time Interval
Datalogger Events
Display Datalogger
Datalogger Setup
Press the <Up/Down Arrow> key and scroll to the [Sonilocate] menu item. Press the
<ENT> key to select it. (A + sign will appear to the left of the menu item.) If desired,
press <CLR> key to deselect menu item.
Continually press the <Left Arrow> key to return to the main menu.
Controlotron
Conforms Operation to user Preferences
Channel /Path Setup
Pipe Data
Gas Parameters
Pick/Install Xdcr
Operation Adjust
Flow/Total Units
Data Span/Set/Cal
Stripchart Setup
Datalogger Setup
I/O Data Control
Diagnostic Data
Dual Path Flow
BCD
Off
On
1 Min.
None
Off
Dual Path
BCD
Controlotron
Select Datalogger Data
Datalogger Mode
Datalogger Data
Log Time Interval
Datalogger Events
Display Datalogger
Datalogger Setup
2-34
1010BXFM-3
Dual Path
BCD
+Sonilocate
+Site Id
+Date
+Time
Flow
+Average Flow
Raw Flow
Total
Vs
Valc
Aeration