Section 5
TERM
NEGFLOW
NETFLOW
NOTOT
Number Index
Numeric Data
Numeric Entry
Numeric Keys
OpSys ROM
Option List
Parameter
POSFLOW
Register
RTD
Site Name
Site Setup
Site Storage Memory
Spacing Index
Spacing Offset
Transducer
Vaer
Vps
Vs
EXPLANATION
Totalizer mode for negative flow total only.
Totalizer mode that combines positive and negative flow totals.
System function that disables the internal Totalizer.
Computed transducer spacing index based on the estimated
sonic velocity measurement. This index cannot be overridden by
installer.
Refers to a value entered into a menu cell. An example would be
the pipe outer diameter.
Refers to a number you type into menu cell that stores numeric
data.
Use the numeric keys to type a numeric value where appropri-
ate.
The read only memory that stores its basic operating instruc-
tions and permanent defaults.
Lists of options presented at menu cells that allow you to select a
either a single item or multiple items (depending on the function
that the menu cell controls).
Refers to value (either numeric or list selection) stored in a
menu cell.
Totalizer mode for positive flow total only.
Refers to a memory location used by the computer to store data
such as the flow total, etc.
Temperature sensors used with energy flow of mass flow sys-
tems.
A user-entered name that meter associates with a stored Site
Setup. You retrieve a particular Site by selecting its name from a
site name list.
A collection of parameters used by the meter to service a specific
site (or location). 1010 allows you to store several independent
Site Setups.
Section of RAM allocated for permanent data storage. This
memory segment stores inactive site setups (including a backup
of active site). The meter's Site Setup storage capacity depends
on the dynamic memory allocation as dictated by each applica-
tion. In addition, the meter uses Site Storage Memory to store
configurable operating parameters such as pipe and liquid tables.
Refers to the Number Index, used by the computer to determine
the space between the upstream and down stream transducers
on clamp-on systems.
Fixed transducer offset assigned by the flow computer. This can
be overridden by the installer.
Clamp-on flow sensors that the meter uses to measure the flow
rate.
The meter's aeration percent output.
The sonic propagation velocity of a pipe wall material.
The sonic velocity of a liquid.
5-8
1010BXFM-3