Section 2
You can change the listed site name by following the procedure below. You may select up to
eight characters. If you decide to use numbers or a decimal point in the site name, you can
type these characters directly from your PC keyboard.
To Save or Rename a Site Setup:
Type the site name with the PC keyboard or use the Magnetic Wand and press
to access the first character position.
To select a character press
To select the second character press
characters (8 max.).
To save the site data present in Active Memory press
If Contolotron's Flowtalk software is used to save or restore sites, you can avoid creating
illegal file names by not using spaces or decimal points (.) in your site names.
2.2

THE PIPE DATA MENU

This menu becomes available after picking a Meter Type, Measurement Channel and Mea-
surement Technology. We recommend that you edit the Pipe Data immediately after creating
a new Site Setup. The Pipe Data menu allows you to define the application's pipe parameters.
Select a pipe from one of the meter's stored pipe tables (see menu structure below); or input
the pipe size and description manually. Manual entries include Pipe Material, Outer Diam-
eter (OD) and pipe Wall Thickness. Liner Material and Liner Thickness entries are included
to support pipes with liners. The meter requires the pipe outer diameter (OD) and wall thick-
ness to operate. You must define these parameters to complete the installation.
The pipe table includes descriptions for over sixty standard pipes plus any user-entered pipes
(see Meter Facilities). To use these presets, first pick a Pipe Class (e.g., ASA Stainless Steel),
then pick a pipe size within that class (e.g., 4SS10). When you select a particular pipe class/
size, the relevant pipe parameters appear in the Pipe Data menu cells. If a given pipe class/
size does not match your application exactly you can still edit each individual parameter to
fine-tune your selection. In addition, the Meter Facilities section of the Installation Menu
provides a pipe table editor that allows you to customize any or all of the stored pipe tables.
NOTE: If you edit the pipe parameters after the system is operating, you will have to
repeat the transducer install procedure.
Use this menu
cell to edit the
pipe outer
Controlotron
diameter.
Select Pipe Class from Pipe Table
Use this menu
cell to edit the
pipe material.
Use this menu
cell to edit the
wall thickness.
Pipe Data
2 Channel
Select Pipe Class
Manual Entry
Select Pipe Size
No Pipes
Pipe OD <in>
0.500
Pipe Material
Steel
Wall Thickness
0.100
Liner Material
None
Liner Thickness
0.000
then
to highlight to next character position.
. Repeat this process to select all the
ENT
[1]
ABC
2-6
1010BXFM-3
.
Use this menu cell to select a Pipe
Class from one of the meter's presets.
The [Manual Entry] selection (default)
means that you enter pipe data
manually.
After picking a pipe class,
use this menu cell to
select a pipe from within
that class.
Use this menu cell to
select a pipe liner
material.
Use this menu cell to edit
the pipe liner thickness.