Section 2
THE I/O DATA CONTROL MENU STRUCTURE (continued)
I/O Data Control
2.8.1 ANALOG OUT SETUP
System 1010 provides current, voltage and pulse-rate analog outputs. Analog Out Setup al-
lows you to assign data functions for these signals. The computer's terminal strip contains the
analog output terminals.
Io (Isolated current)
Pgen (TTL Logic)
LiquIdent m/s
SG
API
3
Kg/m
Base API
3
Base Kg/m
Viscosity
T1
Vs
Siemens Hardware
Relay Setup
Analog Inp Setup
System 1010 Analog Outputs
4 to 20 mA varies in proportion to an assigned data function.
0 to 5000 Hz varies in proportion to an assigned data function.
Analog Out Setup Data Categories
System sonic velocity compensated for temperature.
Current liquid specific gravity.
Current liquid API number.
Current kilograms per cubic meter.
Current system API at reference temperature.
Current kilograms per cubic meter at reference temperature.
Current liquid viscosity.
Current liquid temperature.
Spanned liquid sonic velocity.
Relay 1
S.G
API
kg/m
3
Base S.G.
Base API
Base kg/m
Hi Temperature
Low Temperature
Fault Alarm
Spacing
Empty
Areation
ROC
Off
-
Relay 2
See Relay 1
Iin1/2
Input
4 mA
20 mA
2-47
1010BXFM-3
3
Off
Aux
SG
API
Kg/m
3
cS
cP
PSIA
BARA
Deg F
Deg C
*numeric entry
*numeric entry
(continued)