Press the <Right Arrow> to access the [Select Option List]. Press the <Down Arrow> until
the cursor selects [Diesel Fuel].
Press the [ENTER] key to select [Diesel Fuel]. Note that the screen now lists an estimate
of the liquid's Sonic Velocity (Vs), its Viscosity (in centistokes) and its Specific Gravity
(Density SG). All these parameters can be edited. This allows you to "fine-tune" the liquid
so that it is as close as possible to the actual liquid to be measured.
1.17.4 HOW TO MANUALLY SELECT TRANSDUCERS AND A MOUNTING
MODE
In this section, we'll explore how to override the meter recommendations. Please note that
the modifications shown in the following example are only intended to provide examples of
the meter's flexibility. For this example, we will discuss the procedures required to mount a
set of 1011 Universal transducers of size [C2] in Reflect Mode (see next page).
Controlotron
2 Channel
Access Liquid Option List
Select Liquid
Estimated Vs m/s
Viscosity cS
Density SG
Liquid Class
Controlotron
2 Channel [1]
Initial sonic velocity
Select Liquid
Estimated Vs m/s
Viscosity cS
Density SG
Liquid Class
1-34
[1]
SITE1
Water 175C/347F
Water 200C/392F
Water 225C/437F
Water 250C/482F
Acetic Acid
Alcohol
Bromine
Carbon Tet
Chlorine
>Diesel Fuel
SITE1
Diesel Fuel
1377
2.30
0.000
1010BXFM-3