Section 1
Rotating Display module permits horizontal or vertical mounting.
Menu Lockout Switch prevents unauthorized access to site setup data.
External power and control wiring located in a separate compartment utilizing a hazard-
ous area compliant safety interface to flow and temperature (optional) transducers.

Integral Datalogger

System 1010BX provides an integral Datalogger that records user-assigned data at a pro-
grammable log interval for later retrieval. Data reports can be transmitted via the RS-232
port to either a serial printer for hard copy, or to a laptop computer where the report format
is comma-delimited ASCII text to facilitate its import to spreadsheet or database software.

Analog Outputs

Isolated current loop varies from 4-20 mA in proportion to any user-selected data function.
Isolated Pulse rate output varies from 0-5000 Hz in proportion to any user-selected data func-
tion.
Opto-Coupled Transistor relay trigger output provides TTL logic levels (3-5 Vdc, High, 0-1
Vdc Low) response to user-assigned alarm functions.
1.5

INTRODUCTION TO THE 1010BX OPERATING SYSTEM

The System 1010BX software resides on Flash-Programmed ROM chips. Software upgrades
are easily implemented by simply reprogramming these chips at the factory or in the field. All
1010 models provide a ready reference to the software version and modification code. Addi-
tionally, a check-sum assures that the software code has retained its original integrity. The
operating system consists of real-time data collection and meter control algorithms and an
Installation Menu interface for easy data entry.

1.5.1 INSTALLATION MENU OVERVIEW

For all System 1010 models, site set up is accomplished under the control of an Installation
Menu. The Installation Menu presents all the site setup options consistent with the meter
type to be installed. In other words, the Installation Menu changes to be compatible with the
particular meter type selected at the "top" menu level.
In addition, the operating system allows the factory template to be customized so as to suit
user preferences. This feature is particularly advantageous for users who may need to rou-
tinely re-install the system at different locations within a facility. The system includes a com-
prehensive Diagnostic menu that provides information on current operating conditions, plus
system test and recovery routines.
Please note that you can review site parameters at any time with little danger of altering the
data, since you would have to perform specific keystrokes to affect a change. The meter allows
a site data dump, either to a printer to obtain hard copy, or to a PC for storage as a data file.
Retaining a copy of the site setup is particularly important for flow calibrated systems.

1.5.2 OVERVIEW OF REAL-TIME DATA COLLECTION

Real-time operation commences after the completion of the site setup procedure. The real
time operating software's function is to collect the primary measurement data from the trans-
ducer system and then make it available to be converted to output data by the Data I/O and
Siemens Hardware
Display subsystem.